Description. Compare. Shop for Safety Switches & Disconnects, 60 Amps, 3R IP/NEMA Rating, 240 VAC from Platt Electric Supply. Amperage rating: 60 Amp. Horsepower: 15 HP at 240-Volt, 30 HP at 480-Volt. Includes fusible and non-fusible. Non-Fusible: Manually connect or disconnect the load from the source. VIEW HISTORY. All 2 & 3-pole double throw switches are suitable for use as service equip It has power rating of 20 hp at 480-Volt AC, 25 hp at 600-Volt AC for 1-Phase, 30 hp at 480-Volt AC and 50 hp at 600-Volt AC for 3-Phase. Drops, spills and cracked screens due to normal use covered for portable products and power surges covered from day one. Specifications Sheet. Air Conditioning Disconnect, Pullout, Non-Fused, 60 AMP, 2-Pole, 120/240 VAC, Metallic, Galvanized Steel Enclosure, NEMA 3R. Heavy Duty Safety Switch / Disconnect for heavy industrial, public works, etc. Resource Quick View. 480-208Y120 45kVA; 480-208Y120 75kVA; 480-208Y120 112.5kVA; Need something different? NEMA 1, 3R, 4, 4x, and 12. General duty Safety Switch / Disconnect for residential, light industrial, commercial, through 240 Volt AC only, from 30-600 Amp sizes. Includes fusible and non-fusible. NEMA 1, (General Indoor) and NEMA 3R (Rainproof) only. NEMA 4X 4. Enclosure Rating: NEMA 3R. Non-Fusible Disconnect Switch, 240V AC, 1-Phase, NEMA 3R, Surface Mount, Metallic Enclosure Surface mountable switch features painted galvanized steel construction. Details about GE THPR23608T 800 Amp Main Breaker 480/277V 3 Phase 4 Wire Nema 3R Outdoor Panel See original listing. Be it energy supply corporations, industry or power stations, any owner or user of primary distribution systems for medium voltage places high demands on the switchgear. Manufacturer Information Family Brand Name. What Milbank Does. Enclosure: NEMA 3R Corrosion resistant, baked enamel for an incredibly durable finish. Learn more about our values and commitment to innovation. 480VAC 3-Phase Disconnect; 480-208Y120 Transformer; 208Y/120 3-Phase Panelboard; Standard Sizes. We are a proud American manufacturer and for more than 90 years, we have been innovating for the electrical industry. Manually operated switch fuses from 20 to 1250 Amperes, available for all types of fuses: DIN, BS, NFC, CC, JJ, and L types. Cutler Hammer- Safety Switches / Disconnects. Eaton K Series 3-Pole 4-Wire Heavy-duty safety switch is rated at 60-Amps and 600-Volt AC. Single Throw Safety Switch. Free shipping for many products! Factory Installed Neutral: Neutral (factory installed) Disconnect Type: Fusible disconnect. NEMA 3R 8. Honeywell Commercial 600-Amp Automatic Transfer Switch (120/240V 3-Phase) Sign in to our new website! Enclosure material: galvanized steel. Model: RTSZ600G3. Receive an email when this item is back in stock. The Square D by Schneider Electric 60 Amp 240 Volt 3-Pole 3-Phase Outdoor Fusible General Duty Safety Switch is designed for residential and commercial applications where durability and economy are prime considerations. Typical loads are lighting, air conditioning and appliances. Disconnect Switch, Fused, NEMA 3R, 1200 Amp, 3-Pole, 1200 Volt AC, Factory Installed Neutral, Cat #: H368NR, Mfr: Square D MaxGard Fused Disconnect with Interlocked Receptacle, 60 Amp, 3 Pole 4 Wire, 3 Phase, 480 Volt 60Hz, NEMA 3R/12 A Fully Interlocked Maxgard Receptacle center Ground Contacts: Make First, Break Last. Non-fusible Disconnects are a high performance, compact solution. 60-Amp, 3-pole, 3-wire, 600-Volt non-fusible safety switch; NEMA type 3R: enclosure is intended for outdoor use primarily to provide a degree of protection against falling rain and sleet and must remain undamaged by the formation or ice on the enclosure; they are not intended to provide protection against conditions such as dust, internal condensation or internal icing Voltage: 480 / 600V AC. SQUARE D H362RB FUSIBLE 60A AMP 480V-AC 3P DISCONNECT SWITCH B249748: Amazon.com: 1/2-Inch x 6 Ft Nonmetallic Liquid Tight Flexible Electrical Conduit and 10 Gauge Wire Single Phase Preassembled A/C Hook-up Whip Kit, 1/2" $23.95. The unit is approved for outdoor use and features a metallic enclosure. With our complete range of circuit breaker and switchgear systems for medium-voltage, Siemens sets the standards when it Heavy Duty Safety Switch / Disconnect for heavy industrial, public works, etc. Short Circuit Current Rating: 100 kA maximum depending on fuse H, K or R. fusible; 400 amps @ 600vac 3 phase series: e1 enclosure type: nema 3r . Other sizes, voltages and configurations are available. Siemens Low Voltage Circuit Protection Heavy Duty Safety Switches. Factory-Direct. Heavy Duty Safety Switches, Designed to be tough, reliable and provide exceptional performance in the most grueling conditions. Wattage. 400 amp 3 phase 600 vac 3r square d non fusible safety switch disconnect cat# hu365awk $ 725.00. square d . Compare. Rotary Disconnects. For Use With Watertight Plugs And Inlets Where Portable Equipment Is On Stand By And Plugs Are Not In Use. where reliable performance and service continuity are critical. ABB offers a wide variety of manual change-over switches, from 16 to 3200 Amperes in range. Learn more about 8DA10 single-bus and 8DAB10 double-bus, gas-insulated, arc-resistant, metal-clad 5-15 kV switchgear. Ideal for renewable applications. Learn more about 8DJH 36, gas-insulated, arc-resistant, metal-enclosed 38 kV switchgear. Generac 150-Amp Automatic Smart Transfer Switch w/ Power Management (Service Disconnect ) Model: RXSW150A3 (6) Write A Review Ask a Question $799.00 Free Shipping In-Stock Ships Friday, Aug 5th Shipping to 98848 Update Shipping Details $134 / Month Suggested monthly payments with 6 month financing. Disconnect Switch, Fused, NEMA 3R, 60 Amp, 3-Pole, 600 Volt AC/DC, Heavy Duty. View Details. View Details. Type: 3-phase switch. These include reliable technology, ease of operation, and economy. 240, 480, 600 Volt Type 4X 11. Interrupt rating: 10 kAIC. Free Shipping & Lift Gate. $21.99 . NEMA 3/3R 8. Non-Metallic 14. Ideal for utilities that are close to modernization, Siemens offers Medium-Voltage Replacement Generator Circuit Breakers as replacements for leading OEM models for voltages up to 24 kV and interrupting capabilities up to 100 kA for both indoor and outdoor applications. DISCONNECT COVER, 60A, LED PHASE IND, 4X. Siemens double throw switches are intended to transfer loads from one power source to another. 60A 3P 600V 3W NON-FUSED HD TYPE 3R Siemens HNF362R 240/480/600 VAC 250/600 VDC 60 Amp 3-Pole 3-Wire NEMA 3R Heavy Duty Non-Fusible Safety Switch. 2% Check Discount. 200 Amp 600 Volt 3 Pole w/Neutral Fusible NEMA 3R Raintight Safety Switch Disconnect Heavy Duty. Weight: 80 lbs. Manufacturer: Siemens 600 Volt. Siemens. 240, 480, 600 Volt Square D D322NRB AC Disconnect Characteristics: Line Rated Current: 60 A. Certifications: UL listed. 3 Year Home Improvement Protection Plan from Asurion, LLC . Cutler Hammer- Safety Switches / Disconnects. MaxGard Fused Disconnect with Interlocked Receptacle, 60 Amp, 3 Pole 4 Wire, 3 Phase, 480 Volt 60Hz, NEMA 3R/12 A Fully Interlocked Maxgard Receptacle center Ground Contacts: Make First, Break Last. Give us a call or request a quote! Milbank produces metering products, enclosures and enclosed controls for power distribution. $5,309.00. Furnas Controls HF361R - Fused 3 Pole Disconnect, 480V, 30A, Type H Fuse, Nema 3R Outdoor Enclosure - Fused 3 Pole Disconnect, 480V, 30A, Type H Fuse, Nema 3R Outdoor Enclosure Specifications: Type: Fusible Safety Switch Mounting: Enclosed Poles: 3 Voltage: 480V UL Amps: 30 UL Rating: UL98 Enclosure Type: NEMA 3R Outdoor Fuse: Type H Disconnect Switch, Motor Quick, 3 Pole, 30A 600V AC, NEMA 1 Enclosure, With 1) Pre-Wired LINKOSITY Female Receptacle. Sub Brand. Sq D 30 Amp - 200 Amp 600 Volt FUSIBLE Disconnect NEMA 3R Manufacturer Square D / Schneider Electric Voltage 480/600 Amperage 30 Amp, 60 Amp, 100 Amp, & 200 Amp Enclosure Nema 3r/12 -Outdoor Poles 3 Wires 3 Fuse Provision Fusible Description HEAVY DUTY SAFETY TYPE Type 1 3. Product Literature. COVERAGE: Plan starts on the date of purchase. Color: ANSI 61 gray. 466. NO ADDITIONAL COST: You pay $0 for repairs parts, labor and shipping included. Write A Review. Air Conditioning Disconnect Switch, 60 A, 240/480 V, 3 Phases, 15 HP @ 240 V;30 HP @ 480 V, Galvanized Steel (Enclosure) Material, Gray, #14 to #4 Awg (Cu/Al 60C or 75C) Wire Size, Non Fusible, 5.3 In Overall Length, 3.74 In Overall Width, 8.6 In Overall Height, 4 LB This is a 60 Amp 3-phase molded case switch. Fused - 240 Volt Safety Switches & Disconnects General Duty - Fused General Duty - Fused - 240 Volt - 3 Pole $ 308.40. where reliable performance and service continuity are critical. Part #: 64863-010. 3 Watt. Enclosure: NEMA 3R. For Use With Watertight Plugs And Inlets Where Portable Equipment Is On Stand By And Plugs Are Not In Use. Stainless Steel 28. Find many great new & used options and get the best deals for GE THPR23608T 800 Amp Main Breaker 480/277V 3 Phase 4 Wire Nema 3R Outdoor Panel at the best online prices at eBay! Air Conditioning Disconnect, Pullout, Non-Fused, 60 AMP, 2-Pole, 120/240 VAC, Metallic, Galvanized Steel Enclosure, NEMA 3R. 100 Amp 600 Volt 3 Pole Non-Fusible NEMA 3R Raintight Safety Switch Disconnect Heavy Duty. Poles: 3 (3 Phase) Amps: 200. Dimensions: 32.5 x 20.63 x 24 x 10.63. Includes fusible and non-fusible.